Model:266GST.U.K.B.N.A.1-.EN..L1.B6.....N4..C1
266GST - 266GST Top Performances Gauge pressure transmitter, base accuracy 0.04 %
Sensor Span Limits / Overpressure U 30 and 3000 kPa (0.3 and 30 bar, 4.35 and 435 psi) / 6 MPa (60 bar, 870 psi) Diaphragm Material / Fill Fluid K Hastelloy C-276 / Silicone oil (NACE)
Process Connection Material / Type B AISI 316L SST (1.4404) / 1/2-14 NPT female (NACE)
Gasket Material N None
3 Housing Material / Electrical Connection A Aluminium alloy (Barrel type) / 1/2-14 NPT
Output 1 HART digital communication and 4 ... 20 mA Explosion Protection Certification EN Combined ATEX, IECEx, FM Approvals (USA and Canada)
Integral LCD L1 With integral LCD display
Mounting Bracket Shape / Material B6 For horizontal or vertical mounting on pipe and wall / Carbon steel Configuration (units visible on type label) N4 Standard pressure = in. H2O / psi at 20 °C
Certificates C1 Inspection certificate 3.1 acc. EN 10204 of calibration